Review




Structured Review

Multigen Diagnostics Inc ceramic and metallic multigen plus knee
Ceramic <t>Multigen</t> <t>Plus</t> <t>Knee</t> with BIOLOX ® delta ceramic femoral component.
Ceramic And Metallic Multigen Plus Knee, supplied by Multigen Diagnostics Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ceramic+and+metallic+multigen+plus+knee/pmc03349949-168-9-10?v=Multigen+Diagnostics+Inc
Average 90 stars, based on 1 article reviews
ceramic and metallic multigen plus knee - by Bioz Stars, 2026-06
90/100 stars

Images

1) Product Images from "Ceramic Femoral Components in Total Knee Arthroplasty - Two Year Follow-Up Results of an International Prospective Multi-Centre Study"

Article Title: Ceramic Femoral Components in Total Knee Arthroplasty - Two Year Follow-Up Results of an International Prospective Multi-Centre Study

Journal: The Open Orthopaedics Journal

doi: 10.2174/1874325001206010172

Ceramic Multigen Plus Knee with BIOLOX ® delta ceramic femoral component.
Figure Legend Snippet: Ceramic Multigen Plus Knee with BIOLOX ® delta ceramic femoral component.

Techniques Used:

X-rays of a 75-year-old female preoperative, 5 days and 24 months after the implantation of a Delta Ceramic Multigen Plus Knee with BIOLOX ® ceramic femoral component.
Figure Legend Snippet: X-rays of a 75-year-old female preoperative, 5 days and 24 months after the implantation of a Delta Ceramic Multigen Plus Knee with BIOLOX ® ceramic femoral component.

Techniques Used:

Lateral X-ray 12 months after implantation of a Delta Ceramic Multigen Plus Knee with BIOLOX ® ceramic femoral component. A radiolucent line up to 1 mm is seen in Zone 1.
Figure Legend Snippet: Lateral X-ray 12 months after implantation of a Delta Ceramic Multigen Plus Knee with BIOLOX ® ceramic femoral component. A radiolucent line up to 1 mm is seen in Zone 1.

Techniques Used:



Similar Products

90
Multigen Diagnostics Inc ceramic and metallic multigen plus knee
Ceramic <t>Multigen</t> <t>Plus</t> <t>Knee</t> with BIOLOX ® delta ceramic femoral component.
Ceramic And Metallic Multigen Plus Knee, supplied by Multigen Diagnostics Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ceramic+and+metallic+multigen+plus+knee/pmc03349949-168-9-10?v=Multigen+Diagnostics+Inc
Average 90 stars, based on 1 article reviews
ceramic and metallic multigen plus knee - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
Multigen Diagnostics Inc ceramic and metallic femoral component of the multigen plus knee
Ceramic <t>Multigen</t> <t>Plus</t> <t>Knee</t> with BIOLOX ® delta ceramic femoral component.
Ceramic And Metallic Femoral Component Of The Multigen Plus Knee, supplied by Multigen Diagnostics Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ceramic+and+metallic+multigen+plus+knee/pm20828897-45-12-12?v=Multigen+Diagnostics+Inc
Average 90 stars, based on 1 article reviews
ceramic and metallic femoral component of the multigen plus knee - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

Image Search Results


Ceramic Multigen Plus Knee with BIOLOX ® delta ceramic femoral component.

Journal: The Open Orthopaedics Journal

Article Title: Ceramic Femoral Components in Total Knee Arthroplasty - Two Year Follow-Up Results of an International Prospective Multi-Centre Study

doi: 10.2174/1874325001206010172

Figure Lengend Snippet: Ceramic Multigen Plus Knee with BIOLOX ® delta ceramic femoral component.

Article Snippet: A long-term prospective comparative study with the ceramic and metallic Multigen Plus Knee is in progress in order to compare the clinical results and implant survival rates.

Techniques:

X-rays of a 75-year-old female preoperative, 5 days and 24 months after the implantation of a Delta Ceramic Multigen Plus Knee with BIOLOX ® ceramic femoral component.

Journal: The Open Orthopaedics Journal

Article Title: Ceramic Femoral Components in Total Knee Arthroplasty - Two Year Follow-Up Results of an International Prospective Multi-Centre Study

doi: 10.2174/1874325001206010172

Figure Lengend Snippet: X-rays of a 75-year-old female preoperative, 5 days and 24 months after the implantation of a Delta Ceramic Multigen Plus Knee with BIOLOX ® ceramic femoral component.

Article Snippet: A long-term prospective comparative study with the ceramic and metallic Multigen Plus Knee is in progress in order to compare the clinical results and implant survival rates.

Techniques:

Lateral X-ray 12 months after implantation of a Delta Ceramic Multigen Plus Knee with BIOLOX ® ceramic femoral component. A radiolucent line up to 1 mm is seen in Zone 1.

Journal: The Open Orthopaedics Journal

Article Title: Ceramic Femoral Components in Total Knee Arthroplasty - Two Year Follow-Up Results of an International Prospective Multi-Centre Study

doi: 10.2174/1874325001206010172

Figure Lengend Snippet: Lateral X-ray 12 months after implantation of a Delta Ceramic Multigen Plus Knee with BIOLOX ® ceramic femoral component. A radiolucent line up to 1 mm is seen in Zone 1.

Article Snippet: A long-term prospective comparative study with the ceramic and metallic Multigen Plus Knee is in progress in order to compare the clinical results and implant survival rates.

Techniques: